Sandwich panel SPB WE energy

Sandwich panel SPB WE Energy is available in thicknesses 160 - 230 mm.

It ensures excellent air-tightness and energy efficiency. The application of special solutions with structural details and assembly services provided by skilled and certified contractors enable to decrease energy costs of the building and its CO2 emissions up to 20%. Using Ruukki's solutions you can receive more credits in LEED and BREEAM certification systems.

It is a perfect solution for most buildings and structures, combining high quality with very good technical properties

The filling consisting of non-combustible and environmentally friendly soft mineral wool with low thermal conductivity coefficient ensures very good thermal insulation of this panel. Properly milled core increases air-tightness and provides high sound insulation.

Application:

  • External walls (standard fix)

The information on our website is accurate to the best of our knowledge and understanding. Although every effort has been made to ensure accuracy, the company cannot accept any responsibility for any direct or indirect damages resulting from possible errors or incorrect application of the information of this publication. We reserve the right to make changes.

Properties

Model name
Sandwich panel SPB WE energy
Standard module width
1100 mm
Optional module width (B)
1000 mm
Minimum length
2000 mm
Maximum Length
12000 mm
External facing thickness
0.6 mm
Internal facing thickness
0.5 mm
External Fire Exposure
NRO
Air Tightness
q50 = 1,0 m3/(m2*h) for Ruukki Energy system, entire building
Thickness D (mm) 160 170 180 200 230
Weight (kg/m2) 24.8 25.7 26.6 28.4 31.1
U-value (W/m2K) 0.24 0.23 0.22 0.19 0.17
Sound insulation Rw (dB) 29 29 29 29 29
Reaction to fire A2-s1, d0 A2-s1, d0 A2-s1, d0 A2-s1, d0 A2-s1, d0
Wall fire resistance values & max span horizontal / vertical orientation (m): 160 170 180 200 230
EI 30 7.5 / 7.5 7.5 / 7.5 7.5 / 7.5 7.5 / 7.5 7.5 / 7.5
EI 60 7.5 / 7.5 7.5 / 7.5 7.5 / 7.5 7.5 / 7.5 7.5 / 7.5
Detailed information regarding the application of fire resistance ratings can be obtained from Ruukki Sales.

All properties are declared in accordance with EN 14509 and related standards.

 

Coatings and colors

Materials

FacingCoatingCorrosion classUV resistance Colours
ExternalGreenCoat HIARC MAXC4Ruv4 RAL7035, RAL9006, RAL9007
External PolyesterC3Ruv2-3 RAL1015, RAL5005, RAL7015, RAL7016, RAL7035, RAL9002, RAL9006, RAL9007, RAL9010
InternalPolyesterC3RAL9002, RAL9010
UV resistance describes how well the coating is able to keep its original colour and gloss levels in accordance with EN10169. The higher the class, the better the resistance.

Corrosivity categories describe the outdoor climate conditions in accordance with EN12944. The higher the category, the more corrosive environment.
For external facings of 1000 mm module width only the following colors are available: RAL 9010, RAL 9002, RAL 9006, RAL 9007.

Profile options

Modular width Facing Profile options
1100mm External L, M, R275, R550, F
  Internal L, L25, F
1000mm External L, M, R28, R250, R500, F
  Internal L, L25, F 

Design tools

BIM objects

To make both architectural and structural design work easier, with accurate product information in 3D form, we offer a selection of CAD / BIM -objects for Autodesk Revit and ArchiCAD.

 

Software tools

Traypan-logo

Traypan® software for designing sandwich panels

With TrayPan®, you can design metal faced sandwich panels made by Ruukki. A panel structure can be designed as a single- or multi-span construction. You can easily give, with a few parameters, both suction and pressure loads caused by the wind. The application also calculates the necessary fasteners.

Go to Traypan®

Ordering

Technical documents

Here you can find all technical documents related to Ruukki's sandwich panels. Documents are organised by document type. Click to enter document library.

 

Certificates and approvals

Here you can find all certificates and approvals related to Ruukki's sandwich panels. Documents are organised by document type. Click to enter document library.